General Purpose               Back              

@

AXIAL - NON-POLAR   120Hz

 Capacitance / Size / mA 

D 6 8 10 13 16 18
d 0.6 0.8

 ELECTRICAL CHARACTERISTICS                                                   

 Working Voltage 6.3 V  to 100 V
 Operating Temperature - 40C ~ + 85C
 Capacitance Range 0.47 ~  2,200F
 Capacitance Tolerance 20% 
 DC Leakage Current(A)

0.03 CV or 3 A

( after 3 minutes application of rated voltage )

 Dissipation Factor at 120Hz, 25C

WV(V)

6.3 10 16 25 35 50 63 100

DF(%)

26 24 22 20 16 14 12 10

                                                      For capacitor whose capacitance exceeds 1000uF, 

                                                      the value of DF(%) is increased by 2% for every additional 1000uF

Load Life :  1000 hours with W. V  at  + 85C with the polarity inverted every 250 hours.  

          Capacitance Change:    Within 20% of initial value.

          Dissipation Factor:        Not exceed 150% of initial requirement.

          Leakage Current:           Not exceed the initial requirement.

Shelf Life :  500 hours, no voltage applied at +85C.  

          Capacitance Change:    Within 20% of initial value.

          Dissipation Factor:        Not exceed 150% of initial requirement.

          Leakage Current:           Not exceed 200% of initial requirement.

@


Supertech  copyright 2005.11